Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
The diameter of the suction pipe of the pneumatic mini diaphragm pump shall not be smaller than the diameter of the inlet port of the pump. For example, when the high viscosity fluid is delivered, the diameter of the suction pipe is better than the diameter of the inlet of the pump. The suction piping at the inlet end must be durable and free from wrinkles to create a high vacuum. The diameter of the outlet piping must be at least equal to the outlet diameter or slightly larger to reduce friction losses. All piping and fittings must be sealed and not leaking, otherwise the pump's self-priming capability will be reduced.
Pneumatic micro diaphragm pump installation: If you ignore the installation details, careful planning, research and selection for a long time may still lead to poor pumping effect and affect the service life of the pump.
Location: Noise, safety, and other logic factors often require a location where the equipment should be installed. Parallel installations with conflicting requirements may result in blockages in the area of use and affect the installation of other pumps.
Use: First of all, the position of the pneumatic small diaphragm pump must be easy to use, which will facilitate the daily inspection and commissioning of maintenance personnel.
Air supply: Each pneumatic diaphragm pump should have a vent tube and the vent tube should provide enough air to achieve the desired pumping flow. The air pressure is determined by different pumping requirements, but not more than 7 BAR. (125PSI)
Installation height: Please fully consider the self-priming ability of the pneumatic diaphragm pump to avoid the problem of reduced self-priming.
Piping: The pump position can only be determined after considering each position where a pipeline problem may occur.
The installation of zui should be chosen at the junction of a zui short and zui straight inlet and outlet pipe. Additional bends and fittings should be avoided as much as possible. The pump body should be able to support all lines independently. Moreover, the piping should be arranged in order to avoid stress on the pump piping.
A movable hose can be installed to eliminate the stress generated by the natural reciprocating motion of the pump. To connect the pump body to a fixed base, placing a cushion between the pump body and the base will help reduce pump vibration.
March 04, 2024
September 20, 2024
March 12, 2024
August 09, 2023
November 12, 2024
October 26, 2024
Enviar e-mail para este fornecedor
March 04, 2024
September 20, 2024
March 12, 2024
August 09, 2023
November 12, 2024
October 26, 2024
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.